Optimized Bed Leveling Macros
Introduction
Section titled “Introduction”These optimized macros strike a balance between safety and time efficiency by combining the benefits of large and small Z-Hop values. The leveling procedure is divided into two passes:
Pass 1: Initial Coarse Leveling
- Utilizes a large Z-Hop value to prevent scratching the print surface
- Minimizes probing samples to quickly determine bed position
- Relaxes tolerance requirements to ensure bed levelness within 1mm
Pass 2: Fine Leveling and Accuracy
- Employs normal settings for accuracy and retries
- Reduces Z-Hop distance, leveraging the knowledge that the bed is already approximately level
This two-pass approach ensures a efficient and safe leveling process, optimizing time savings while maintaining accuracy.
QUAD_GANTRY_LEVEL (Voron 2.4)
Section titled “QUAD_GANTRY_LEVEL (Voron 2.4)”This macro renames and extends the existing QUAD_GANTRY_LEVEL command, implementing the two-pass leveling process. By replacing the default functionality, no additional modifications to the configuration are required. The macro executes the following steps:
Pass 1: Initial Coarse Leveling - Lifts the head to 10mm
Pass 2: Fine Leveling - Lifts the head to 2mm
[gcode_macro QUAD_GANTRY_LEVEL]rename_existing: BASE_QUAD_GANTRY_LEVELgcode: # Pass 1: Initial Coarse Leveling BASE_QUAD_GANTRY_LEVEL HORIZONTAL_MOVE_Z=10 RETRY_TOLERANCE=1 # Pass 2: Fine Leveling and Accuracy BASE_QUAD_GANTRY_LEVEL HORIZONTAL_MOVE_Z=2Z_TILT_ADJUST (Voron Trident)
Section titled “Z_TILT_ADJUST (Voron Trident)”This macro renames and extends the existing Z_TILT_ADJUST command, implementing the two-pass leveling process. By replacing the default functionality, no additional modifications to the configuration are required. The macro executes the following steps:
Pass 1: Initial Coarse Leveling - Moves bed down by 10mm
Pass 2: Fine Leveling - Moves bed down by 2mm
[gcode_macro Z_TILT_ADJUST]rename_existing: BASE_Z_TILT_ADJUSTgcode: # Pass 1: Initial Coarse Leveling BASE_Z_TILT_ADJUST HORIZONTAL_MOVE_Z=10 RETRY_TOLERANCE=1 # Pass 2: Fine Leveling and Accuracy BASE_Z_TILT_ADJUST HORIZONTAL_MOVE_Z=2Optional Tuning Parameters
Section titled “Optional Tuning Parameters”The following parameters in the macros can be adjusted to futher optimize the leveling process:
- HORIZONTAL_MOVE_Z: Specifies the intermediate move height (in mm) between probes
- RETRY_TOLERANCE: Defines the maximum allowable deviation between the largest and smallest probed points, triggering retry leveling if exceeded
- SAMPLES: Specifies the number of probe samples to use per leveling point